📖 Properties of gas mixtures (and of gas with vapour)
A mixture of perfect gases acts like one equivalent gas with its own molecular mass M and gas constant R, so P V = m R T still works. Its u, h, cp and cv are mass-weighted sums of the gases'. For entropy each gas counts at its own partial pressure, so mixing raises it. A vapour in air (moist air) is one more gas, but it can never pass p_sat.
- Equivalent molecular mass M = Σ y_i M_i; equivalent gas constant R = R̄ / M = Σ x_i R_i.
- U = Σ m_i u_i, H = Σ m_i h_i; per kg: cp = Σ x_i cp_i, cv = Σ x_i cv_i.
- Entropy: each gas at T and its partial pressure p_i; ΔS_i = m_i (cp_i ln(T₂/T₁) − R_i ln(p₂/p₁)).
- Mixing gases at the same P, T: ΔS = −R̄ Σ n_i ln y_i > 0 (irreversible).
- Gas + vapour: p = p_a + p_v; the vapour's h, s come from the steam tables at (p_v, T).
- Moist air: ω = 0.622 p_v / (P − p_v); h = cp_a t + ω h_v per kg of dry air.
More detail (for the exam) ▾
M = Σ y_i M_i · R = R̄/M = Σ x_i R_i · cp = Σ x_i cp_i · cv = Σ x_i cv_i · γ = cp/cv
ΔS_mix = −R̄ Σ n_i ln y_i · ω = 0.622 p_v/(P − p_v) · φ = p_v/p_sat · h = cp_a t + ω h_v
📝 Exam note: write it like this
u, h, cp, cv: m u = Σ m_i u_i, m h = Σ m_i h_i, so cp = Σ x_i cp_i and cv = Σ x_i cv_i (and still cp − cv = R). On a mole basis use y_i with molar specific heats.
Entropy: each gas behaves as if alone at the mixture T and its partial pressure (Gibbs–Dalton law), so S = Σ m_i s_i(T, p_i). Mixing at the same P, T: ΔS = Σ m_i R_i ln(P/p_i).
Gas–vapour mixtures: the vapour is treated as a gas at its partial pressure; when p_v reaches p_sat at the mixture temperature it is saturated and further vapour condenses (dew point).
⚠️ Common mistakes
- Averaging cp or R with MOLE fractions: per-kg properties take mass fractions.
- Using the total pressure for each gas's entropy: use its partial pressure.
- Thinking mixing at constant T and P changes nothing: the entropy rises.
- Letting the vapour pressure rise above p_sat(T): the extra vapour condenses.
All mixes and numbers are our own, from our tested mixture model and IAPWS-IF97 steam tables (dry air cp = 1.005 kJ/kg·K, M = 28.97).