📖 P–v–T surface, T–s and h–s diagrams
For a pure substance any two independent properties fix the state, so P, v and T together make a surface. Look at it along the T axis and you see the P–v diagram; along the v axis, the P–T (phase) diagram. T–s and h–s diagrams show the same states with entropy across.
- P–v–T surface: every equilibrium state of the substance is a point on it.
- The two-phase region is a ruled strip: at each T the pressure stays at Psat as v grows.
- P–v diagram = the surface seen along T; the dome, with flat isotherms inside.
- P–T diagram = the surface seen along v; each wet strip is just a line (phase diagram).
- T–s diagram: area under a reversible process = heat; boiling is a flat line.
- h–s diagram: a reversible adiabatic (turbine) process is vertical; its height = work.
More detail (for the exam) ▾
Wet region: s = sf + x sfg, h = hf + x hfg, sfg = hfg / Tsat · T ds = dh − v dP
T–s: q_rev = ∫T ds (area) · h–s: slope (∂h/∂s)_P = T · isentropic turbine: w = h₁ − h₂
📝 Exam note: write it like this
Projections: projecting the surface on the P–T plane gives the phase diagram (sublimation, fusion and vaporisation curves meeting at the triple point; the vaporisation curve ends at the critical point). Projecting on the P–v plane gives the saturation dome with isotherms.
T–s diagram: constant pressure lines are horizontal inside the dome and rise steeply in the superheated region; constant volume lines are steeper than constant pressure lines.
h–s diagram (Mollier): in the wet region constant pressure lines are straight (slope = Tsat); isentropic processes are vertical lines, so the enthalpy drop (work) is read straight off.
⚠️ Common mistakes
- Thinking the P–T diagram has a dome: on P–T the wet region is only a line.
- Reading the area under a line on h–s as heat: on h–s the vertical distance is the change in enthalpy; area means heat on T–s.
- Forgetting that boiling is horizontal on both P–v (P constant) and T–s (T constant).
- Drawing a turbine expansion as horizontal on h–s: reversible adiabatic means s constant, a vertical line.
Surface and diagrams from our own IAPWS-IF97 steam core (tested against the IAPWS verification tables); log scales for v and P. Solid region not shown. All examples are our own.