📖 Steam quality: dryness fraction, steam tables, Mollier chart, calorimeters
Steam in a pipe is often wet: steam with tiny water drops. Its dryness fraction x is the mass of steam in each kg of the mixture. The steam tables give the properties of water (f) and steam (g) at each pressure, so any wet state is f + x·fg; the Mollier chart plots the same h and s as a picture. A calorimeter measures x of real steam.
- Dryness fraction x = mass of vapour / total mass: 0 = water, 1 = dry saturated steam.
- Tables: v = vf + x·vfg, h = hf + x·hfg, s = sf + x·sfg (fg = g − f).
- Mollier chart: h up, s across; isobars cross the dome straight, then curve up into superheat.
- Throttling calorimeter: h₂ = h₁; read P₂, T₂ (superheated) → x = (h₂ − hf₁)/hfg₁.
- Separating calorimeter: x₁ = M/(M + m). Combined: x = x₁·x₂, for very wet steam.
- Processes: rigid tank W = 0, Q = Δu; constant P: Q = Δh; isentropic: Q = 0, W = u₁ − u₂.
More detail (for the exam) ▾
x = m_vapour / (m_vapour + m_liquid) · v = vf + x vfg · h = hf + x hfg · s = sf + x sfg · u = h − P v
Throttling: hf₁ + x hfg₁ = h₂ (P₂, T₂) · Separating: x₁ = M/(M + m) · Combined: x = x₁ x₂
📝 Exam note: write it like this
Mollier chart: an h–s chart with lines of constant pressure, temperature, dryness and volume; throttling is a horizontal line, isentropic expansion a vertical line.
Calorimeters: throttling (needs superheat after the throttle, so only for fairly dry steam); separating (mechanical, catches most drops, x₁ a little high); combined separating-throttling gives x = x₁ x₂.
Processes with steam: use the tables for u, h, v and the first law Q − W = Δu: constant volume W = 0; constant pressure W = P(v₂ − v₁), Q = h₂ − h₁; reversible adiabatic s₁ = s₂, W = u₁ − u₂.
⚠️ Common mistakes
- Using hg instead of hf + x·hfg for wet steam.
- Using the throttling calorimeter alone on very wet steam: it never gets superheated.
- Writing Q = Δh for a rigid tank: no boundary moves, so Q = Δu.
- Treating steam as an ideal gas: read the tables.